Transformer Oil Filtration Unit
video
Transformer Oil Filtration Unit

Transformer Oil Filtration Unit

ZJB series transformer oil filtration unit is mainly used to improve the properties of insulation oil, transformer oil. It can remove trace water, gas, impurities etc. From the insulating oil, electric oil and transformer oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which have insulation system.
Αποστολή ερώτησής
Περιγραφή

Usage scope

ZJB series transformer oil filtration unit is mainly used to improve the properties of insulation oil, transformer oil. It can remove trace water, gas, impurities etc. From the insulating oil, electric oil and transformer oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which have insulation system.

double stage vacuum transformer oil purifier

Online work notes:

The first is preparation:

1. Prepare the qualified oil with 5-6 percent of the transformer oil filling amount and put it next to the oil filter;

2. The oil drain valve port at the bottom of the transformer should be matched with the oil inlet pipe of the oil filter.

3. The transformer oil filtration unit should be equipped with qualified oil of 1/2 of the oil standard pipe of the vacuum tank (pressure resistance value Greater than or equal to 50KV);

4. Open the oil pillow cover of the transformer, insert the oil outlet pipe of the oil filter into the oil level on the oil pillow, and then seal the oil pillow cover with clean filter paper or film;

5. Insert the oil inlet pipe of the oil filter into the oil drum prepared with qualified oil;

6. Open the oil drain valve at the bottom of the transformer, and drain 3-5 percent of the oil of the transformer (the 3-5 percent oil is mainly impurities and water, which should be connected and discharged separately);

7. At the same time as step 6, the oil filter should be made into a high vacuum (not less than -0.09MPa), and the oil level of the transformer oil pillow should be replenished immediately;

8. When the oil drain valve at the bottom of the transformer discharges 3 to 5 percent of the "waste oil", connect the oil inlet pipe of the oil filter to the oil drain valve;

9. At this time, the transformer oil filtration unit can work normally.


Technical Specification

Item

Unit

ZJB

-10

ZJB

-20

ZJB

-30

ZJB

-50

ZJB

-75

ZJB

-100

ZJB

-150

ZJB-200

Flow rate

L/H

600

1200

1800

3000

4500

6000

9000

12000

Vacuum degree

Mpa

-0.06 -0.098

Working pressure

Mpa

Less than or equal to 0.4

Fault free

H

4000

Working temperature

degree

20-80

Continuous working time

H

150

Power supply


380V/50Hz (or as per requirement)

Noise

dB(A)

Less than or equal to 75

Less than or equal to 80

Heating power

kW

9

15

18

30

48

60

90

105

Total power

kW

11

17

21

33

53

65

96

116

Inletoutlet size

mm

25

25

25

32

40

40

50

60

Weight

Kg

380

400

420

510

550

730

960

1200

Size

L

mm

1050

1150

1200

1300

1600

1600

2100

2200

W

mm

750

800

800

900

1000

1200

1500

1600

H

mm

1400

1450

1500

1600

1800

1850

2000

2100

high vacuum oil purifier choose